|
Wake Forest Physics
|
WFU Physics Colloquium
TITLE:
X-Ray Scatter Computation and Simulation in Cone Beam Computed
Tomography
SPEAKER:
Jie Liu
TIME: Wednesday July 29, 2015 at 10:00 AM
PLACE: Room 107 Olin Physical Laboratory
ABSTRACT
In cone beam computed tomography (CBCT) with large object volume within
the x-ray field, the measured signal can be contaminated by a large
amount of scatter photons due to x-ray interactions with the irradiated
object. Scatter can severely degrade the quality of the reconstructed CT
images by creating artifacts and quantification errors. Thus scatter
correction has become an important processing step for improving image
fidelity in CBCT. Algorithm-based methods proposed in the literature
include analytical calculations, Monte Carlo (MC) simulations and
superposition calculations. Analytical and MC methods apply
well-established physical models describing scattering interactions to
accurately calculate or simulate scatter profiles. The prevailing
challenge is the expensive computation cost inherently required.
Superposition methods use simplified object model and are
computationally efficient. But the detailed object information is not
considered and inferior accuracy can occur. Therefore, an optimal method
with balanced performance in computation speed and accuracy is of the
investigation interest.
An analytical model was first proposed to
efficiently calculate the dominant Compton single scatter component.
Dimensional reduction technique was applied to reduce the computation
complexity. Electron binding effect, etc. were also investigated and
accommodated in a more general form. To validate the model, MC
simulations as the reference results were performed in various
scenarios. A comprehensive frame was later developed to cover all
scatter components including Compton, Rayleigh single and multiple
scatter. A long series of MC simulations were performed to create
databases pertaining to scatter parameters for implementation in
calculations that were based on both detector measurement and object
information.
A compact form for the line integration of Compton single
scatter was obtained. The proposed model for Compton single scatter
showed highly improved computation efficiency compared to conventional
analytical method. Databases for beam scatter kernel were obtained and a
general form was parameterized. The comprehensive scatter calculation
method was evaluated in both accuracy and computation speed and showed
balanced performance in both aspects for potentially practical
applications.
|